GLASSvent Ultra Thermal Windows

Windows

GLASSvent® UT (Ultra Thermal) Windows

Never has something so seamless offered so much thermal performance. GLASSvent® UT (Ultra Thermal) Windows are visually frameless concealed vents designed to provide a ventilation option for curtain wall with high thermal performance.

  • 3-1/8″ (79.4mm) or 3-7/8 ” (98.4mm) depth (CW)
  • 4-3/8″ (111.1mm) or 5-1/8″ (130.2mm) depth (AW)
  • Commercial grade window (CW) and architectural grade window (AW)
  • Ultra-thermal performance
  • Casement or projecting configuration
  • Blast mitigation (AW only), hurricane resistance (AW only)
  • Tested to US and Canadian standards
  • 45° mitered vent and frame corners
  • Staked corner joinery
  • Architectural anodized finishes and applied coatings
  • Large missile and small missile hurricane impact tested – AW (deep) only
  • Blast mitigation tested – AW (deep) only
  • Trim cap available in #29 black anodized finish only

Architectural Grade

  • CW-PG70-AP / AW-PG90-AP – projecting
  • CW-PG70-C / AW-PG90-C – casement

Purpose built with accessibility in mind

Kawneer has a functional and aesthetically pleasing ADA-compliant operating handle option for GLASSvent® UT (Ultra-Thermal) Project Out Windows.

  1. Available on AW Version (4 3/8”/111.1 mm depth), project-out awning GLASSvent® UT Windows up to standard AAMA gateway test size.
  2. The handle has been laboratory-tested and proven.
  3. The ergonomic and stylish Omni Drive™ operator from Caldwell features an attractive design with its easy-to-use horizontal handle movement and comes in two sizes: a 12” handle size for ADA compliance and an 8” handle size for other non-ADA applications.

This option provides a solution to meet the Americans with Disabilities Act (ADA) recommendation that operable windows require no more than a five-pound operating force* while also providing a complimentary handle for non-ADA applications.

*Laws and building and safety codes governing the design and use of glazed window products vary widely. Seller does not control the selection of product configurations, operating hardware or glazing materials, and assumes no responsibility.

Thermal Technology

Find out more here.

Blast Resistant

Find out more here.

Hurricane Resistant

Find out more here.

Related Product Approvals

Find out more here.

GLASSvent® UT Windows - Architectural Detail Manual
1 MB
Product Selection Guide Windows
588 KB
Product Selection Guide Hurricane Resistant Windows
472 KB
Product Selection Guide Blast Mitigation Windows
186 KB
GLASSvent® UT Windows - Flyer
731 KB
Kawneer Window Accessories
302 KB
Florida Product Approval & Texas Dept. of Insurance Evaluation Documents
274 KB
GLASSvent® UT Windows - Product Green Guide
271 KB
GLASSvent® Windows - EPD
808 KB
GLASSvent® Windows for Storefront and Curtain Wall / GLASSvent® UT Windows - DECLARE Label
901 KB
GLASSvent® Windows for Storefront and Curtain Wall / GLASSvent® UT Windows - MTS
436 KB
Finishes Brochure
5 MB
Finishes Information - Architectural Detail Manual
238 KB
Anodize Finishes - Color Chart
82 KB
Liquid Paint - Color Chart - Permadize®
1 MB
Liquid Paint - Color Chart - Permafluor™
350 KB
GLASSvent® UT Ultra Thermal Window - English
GLASSvent® UT Ultra Thermal Window - French

Download All
CW-Project-Out and Casement Outswing Details (1" Infill)
AW-Project-Out and Casement Outswing Details (1" Infill)
CW-Project-Out and Casement Outswing Shallow Details (1-3/4" Infill)
AW-Project-Out and Casement Outswing Details (1-3/4" Infill)
AW-Project-Out and Casement Outswing Details (1" Blast Mitigation Infill)
AW-Project-Out and Casement Outswing Details (1-3/4" Blast Mitigation Infill)
AW-Project-Out and Casement Outswing Details (1" Small Missile Impact, Large Missile Impact Infill ≤ 90 PSF)
AW-Project-Out and Casement Outswing Details (1-3/4" Small Missile Impact Infill ≤ 90 PSF)
AW-Project-Out and Casement Outswing Details (1-3/4" Large Missile Impact Infill ≤ 90 PSF)
Download All
Window-2500_UT_Unitwall_System-GLASSvent-1.75in_Infill.rfa
Window-2500_UT_Unitwall_System-GLASSvent-1in_Infill.rfa

While most of our products are not hazardous in and amongst themselves, hazardous properties can develop when the product is altered through cutting, welding, and grinding.  Details on the specific hazards that can develop and the proper protective measures to use can be found in the SDSs.

Arconic’s SDS database provides PDF files of safety information on specific materials.  The SDS ID numbers (product code) and description for materials used in Kawneer products are listed below.

SDS # DESCRIPTION / TITLE
1405 – Kawneer Thermal Break Filled Extrusions
1385 – Kawneer Acrylic Paints
1386 – Kawneer Fluoropolymer Paints

1526 – Kawneer Bloomsburg Solvent Recovery Still Residuals

1387 – Painted Architectural Aluminum Extrusions
509 – Aluminum Extrusions, Anodized Aluminum Products

 

Search Arconic’s SDS database for safety information on specific materials.

 

Warranty Disclaimer TBC

Project Warranty Cover Sheet (English)
137 KB
Project Warranty Cover Sheet (French-Canadian)
137 KB
Project Warranty Cover Sheet Sample (English)
139 KB
Project Warranty Cover Sheet Sample (French-Canadian)
140 KB
Material & Workmanship - English
183 KB
Material & Workmanship - French
190 KB
Material & Workmanship Sample (English)
198 KB
Material & Workmanship Sample (French Canadian)
212 KB
Anodized Finishes Warranty - English
523 KB
Anodized Finishes Warranty - French
517 KB
Anodized Finishes Sample (English)
529 KB
Anodized Finishes Sample (French Canadian)
524 KB
Painted Finishes Warranty - English
557 KB
Painted Finishes Warranty - French
538 KB
Painted Finishes Sample (English)
565 KB
Painted Finishes Sample (French Canadian)
550 KB
Insulating Glass Warranty - English
498 KB
Insulating Glass Warranty - French
499 KB
Insulating Glass Sample (English)
502 KB
Insulating Glass Sample (French Canadian)
504 KB
Laminated Glass Warranty - English
122 KB
Laminated Glass Warranty - French
123 KB
Laminated Glass Sample (English)
126 KB
Laminated Glass Sample (French Canadian)
128 KB